Chengdu Jiuyin Technology
1.1. Daily maintenanceRoutine maintenance is mainly to clean the instrument probe regularly to prevent dust blockage and affect measurement accuracy. Follow these steps when cleaning the meter probe:
Loosen the fixing bolts of the mounting flange and take out the probe : If the equipment is in the state of shutdown (the furnace has been shut down for at least 1 hour), the user can disconnect the probe after the instrument is powered off; if the equipment is in the open state, and the humidity value is higher than Large, in order to avoid damage caused by moisture condensation, please be sure to keep the probe under power supply. If the condition of the site must be powered off, remove the probe. Make sure that the instrument is powered off for less than 1 minute. Check the probe end. porosity, such as in the presence of dust clogged gently removed with a slotted screwdriver soil vent attached to the probe, and blown clean with compressed air (e.g., clogging of dust does not dry, the instrument may remain energized until the dust is then to dry Clean) ; Install the probe as described in section 6.1 Probe Installation Instructions in this user manual .Note: It should be handled gently to avoid bumps.
1.2. Common faults and their solutionsSerial number
Common malfunctions
the reason
Approach
1
Display value error is large
Display value fluctuates greatly
Appropriate increase in filter depth
Sensor drift
Calibrating the hygrometer
Condensed water inside the sensor causes the measured value to be high
Install the meter as far as possible ( refer to Section 6.1 Probe Installation )
High humidity at the site and high dust lead to filter blockage
As for the dust clogged, it can clean up the dust out clogged; the larger site humidity and dust, it is recommended to buy together with dust cover when purchasing hygrometer.
If there is more oil, the end filter cover must be replaced.
Sensor damage
Return to factory to replace the sensor
2
Meter 4-20mA analog output is incorrect
External wiring error
Check that the polarity of the connection is correct
Analog output upper and lower limit setting error
Reset
Disconnect the cable and test the output current value correctly with a multimeter.
The conversion resistance of the AD module is not within the required range, or the wiring is incorrect.
Disconnect the cable and test the output current value with a multimeter incorrectly.
Instrument internal circuit failure, return to factory maintenance
3
The instrument local display and remote display values ​​deviate greatly
Local and remote device analog output upper and lower limits are inconsistent
The upper and lower limits of the instrument is the same as the remote device (refer to chapter 8. The operation menu settings menu)
Analog output calibration is not accurate
Recalibrate the analog output using standard metering instruments
Signal interference
It is recommended to install a signal isolator
4
The instrument test value is obviously high (error is greater than 10%)
Water condensation inside the probe
Remove the probe from the flue and put it in the air for 24 hours to evaporate the water and re-inject the probe into the flue. If it still does not work properly, it needs to be returned to the factory.
Note: The meter probe should be tilted down.
5
The display does not display content
The circuit is not connected
Check circuit connection
Display or hardware circuit failure
Contact the manufacturer for repair
Water is inside the meter, causing damage to the meter
Contact the manufacturer for repair
6
The indicator light FA is bright
Internal memory failure
Return to factory maintenance
Analog output upper and lower limit setting error
Reset
Sensor failure
Return to factory maintenance
7
Sensor damage
Sensor corrosion damage
Return to factory maintenance
Super temperature use
Unknown factor damage
2. WarrantyInstruments must use the correct way to install at a specified user manual normal operating conditions, use and maintenance. If the product has quality problems, all repaired or replaced products are subject to the free warranty terms during the warranty period .
Jiu Yin Technology Chengdu Co., Ltd. is not responsible for any direct or indirect damages or losses resulting from the installation, disassembly and replacement, but not limited to installation, disassembly and replacement. In order to avoid unnecessary disputes, users should return their doubtful products to Jiu Yin Technology Chengdu Co. , Ltd. , after confirming the problem by Jiu Yin Technology Chengdu Co., Ltd. , determine the return, repair or replacement. Users assume the risk of long products sent Yin Technology Co., Ltd. Chengdu process may exist for a long Yin Technology Co., Ltd. Chengdu risk products sent back to the client process may exist.
Warranty Content: In normal use, all materials and instruments shortcomings processes are under warranty contents, but the serial number on the tag warranty instrument can not be lost or torn. Warranty period: The warranty period is one year from the date of purchase. Warranty method: For the repaired instrument during the warranty period , we can repair it, or replace it according to the situation. We can use new or reworked parts for the replaced instrument , and also have the right to provide an upgraded version of the original instrument model. Warranty Restriction: In addition to repairing or replacing the instrument , we solemnly draw your attention to the following conditions, which are not covered by the manufacturer's warranty. For this type of faulty instrument, we will provide a quotation and charge: after receiving the product, due to the carrying Damage caused by improper transportation or storage (eg broken display, deformation of the casing, water ingress to the instrument, dust or corrosive environment, etc.); damage to the instrument due to negligence, mishandling, accident or force majeure (eg poor grounding) Or wiring error) and normal wear of mechanical parts; over-temperature, over-range use causes damage to the sensor ; disassembly, modification or replacement of the original instrument ; loss of time due to instrument failure, inconvenient loss and other resulting Indirect losses; instruments purchased from unauthorized sources may not be covered by warranty. How to get warranty service directly to the manufacturer's technical staff, they will tell you how to handle the instrument and provide the corresponding components. If you purchase an instrument from our distributor, you can contact the authorized distributor directly for repair. 3. Transportation and storage 3.1. TransportationThe instrument can be transported by car, airplane, ship, train, etc. in the case of good packaging, and should be protected from direct rain and snow during transportation. Please be careful when handling, do not stress.
3.2. CustodyThe packaged product should be stored at a temperature of -20 ~ +65 °C , a relative humidity of not more than 80% RH at 25 °C , and a corrosive atmosphere with no acid or alkaline atmosphere.
The instrument should be stored in a location that is dusty, smokeless, free of steam, and non-corrosive.
The induction door lock is a kind of door lock that can be sensed by ultraviolet or infrared rays. This kind of door lock can achieve the effect of opening and closing the door through these hurriedly. The anti-theft effect of the induction door lock is relatively strong, because this kind of door lock is similar to the fingerprint lock, and the induction door lock will remember a certain kind of ultraviolet or infrared to realize the opening and closing of the door.
The door lock circuit board is made of three-proof treatment according to military standards, which is anti-corrosion and durable. The lock core of the door lock adopts a five-bolt structure, which is anti-insertion, and is safer.
It has a completely independent mechanical emergency unlocking mechanism. The emergency unlocking mechanism and the electronic unlocking mechanism adopt two completely independent transmission devices, which greatly improves the reliability of the door lock.
The open interface facilitates the connection with the hotel management system software and provides hardware card reading equipment to realize the all-in-one card.
Induction Lock,Intelligent Induction Door Lock,Intelligent Induction Door Lock For Hotel,Smart Induction Lock
Dongguan Kaisijin Intelligent Technology Co., Ltd , https://www.dgsmartlockoems.com