1 Stability:
The yellow medicine is easily decomposed by water, acid and heat, that is, it is greatly affected by pH and temperature, so the yellow medicine is extremely unstable.
After decomposition, the ability to capture is lost, so xanthate is often used in alkaline pulp. Decomposition rate in an acidic environment: low-grade xanthate > advanced xanthate, so when used in an acidic medium, try to use advanced xanthate.
2 Oxidizing properties:
Xanthate itself is a reducing agent and is easily oxidized. When O2 and CO2 are present simultaneously, the oxidation rate is faster than when only O2 is present. Xanthate is oxidized to form a double xanthate
Xanthate in aqueous solution, if certain metal cations, then they will be oxidized xanthate xanthate pairs.
Yellow drug harvesting performance :
1 The ability to affect the recovery of xanthate is the length and heterogeneity of the hydrocarbon chain of the non-polar group in the xanthate molecule. The excessive length of the hydrocarbon chain will reduce the ability of the xanthate to collect, and the number of carbon atoms is usually 2 to 5. The number of short hydrocarbon chain xanthates in the range of 2 to 5, the normal body has no strong isomers for collection. The number is >5 long hydrocarbon chain xanthates, and the isomers are not strong in the normal form.
2 The pro-solid atom of xanthate is sulfur, which can capture metal sulfide minerals. Xanthate has no catching effect on gangue minerals in sulfide ore. The xanthogenate formed by the reaction of xanthate with alkaline earth metal ions is easily soluble in water.
Fan Coil
Fan coil unit as terminals of Central Air Conditioner. Equipped with main air cooled chiller or Water Cooled Chiller to cool or heat the target place.
Characteristics:
1.Durable construction. Casing of Lark fan coil units shall be galvanized steel panel. And the condensate pan is treated by extruded seamless technology to prevent the leakage. Fire rated thermal insulation is attached to the condensate pan
integrally. Construction of the units is sturdy and permanent.
2.High efficiency. Coils shall be fabricated by Φ9.25mm cooper tubes and hydrophilic aluminum fins. Tubes are expanded
into the fins accurately to confirm the heat transfer efficiency. Fans shall be high airflow rate and low noise
design. And brass headers of copper tubes well distribute water flow configuration to assure optimum heat
transfer efficiency.
3.Low noise and operating cost. Fans shall be specially designed with over-sized galvanized multi-blade centrifugal wheel, operating with low noise, high static pressure and airflow rate. And hi-static, permanent split capacitor motors shall be factory
balance tested for proof the high efficiency and quite operation.
4.Easy maintenance. Motors shall be fabricated with rolling bearing and quenched and tempered steel shaft with antirust treated. Three-speed or LCD thermostat is convenient to control the airflow and room temperature.
5. Low installation cost. Units shall be low-weight design. Drain pipes and wires are easy for connection. The water connection direction and air return are changeable according to the site requirements.
1. Exposed Fan Coil unit
Air flow: 340m3/h-2380m3/h, Cooling capacity: 1800W-12600W
2.Concealed Fan Coil Unit
Air flow: 340m3/h-2380m3/h, Cooling capacity: 1800W-12600W
3. Cassette Fan Coil
Air flow: 340m3/h-2380m3/h, Cooling capacity: 2000W-12800W
4.Wall Mounted Fan Coil
Air flow: 340m3/h-1360m3/h, Cooling capacity: 1808W-7210W
5.Chilled Water Fan Coil
Air flow: 340m3/h-2380m3/h, Cooling capacity: 1800W-12600W
6. Ducted Fan Coil
Air flow: 340m3/h-2380m3/h, Cooling capacity: 1800W-12600W
Fan Coil
Fan Coil,Fan Coil Radiators,Concealed Fan Coil,Chilled Fan Coil
Jinan Amrta Air Conditioning Co.,Ltd , https://www.amrtaac.com