Anti-static clothing testing equipment as an important anti-static clothing anti-static performance of the testing equipment, in the use of the process must follow the operating procedures and precautions, the following are some of the equipment in the test need to pay attention to matters:
First, the fabric friction electric charge tester is to measure the charge of the antistatic clothing after the friction charged test equipment, the use of the process should pay attention to the following points:
1. The supporting Faraday cylinder tube should be reliably grounded 2. The charge measuring device should be cleared before every experiment. 3. The measured object must be separated from the power source during the measurement. 4. Before the test, turn on the power switch to allow the machine to warm up for 15 minutes. Lined work clothes should be turned outwards, cold clothes should be removed after test liners and linings should be removed. 6. The roller friction machine should be placed on a stable table or on the ground, so as to avoid the operation is swinging and produce more noise. 7. Pins, coins, and Other sharp metal objects are thrown into the roller friction machine to avoid damaging the inner lining cloth 8. The environmental conditions for the antistatic overalls test are temperature (20±5)°C, relative humidity 40%, and point-to-point resistivity test. The instrument is a testing device for testing the resistivity of antistatic clothing. Please pay attention to the following points during use:
1. The built-in battery and external power supply can only select one of the power supply modes. Generally, it is recommended to select the external power supply. 2. When the instrument is not in use, place it in a dry and ventilated place. 3. If it is powered by the built-in battery, if it is not used for a long time, please Remove the battery from the battery compartment to prevent the battery from leaking to corrode the instrument. 4. Non-professional service personnel must not open the instrument cover to prevent electric shock from high pressure inside the instrument. Freely open the cover to disassemble, change the internal components of the instrument may lose the qualification of the instrument or increase the cost of repairs. 5, it is forbidden to use hydrochloric acid, solder paste and other corrosive fluxes to solder the measurement leads, connectors or internal components of the instrument. , In order to avoid irreparable leakage failure Third, the tensile testing machine is to detect the tensile strength of ESD clothing, breaking strength and elongation at break testing equipment, please note the following points during use:
1. The sensor equipped with this instrument is a precision device. It should avoid the impact and distortion of external force. 2. The instrument is equipped with a limit switch for the upper clamp head. When the upper clamp reaches the upper and lower limit positions, the instrument is self-protected and clamped. Stop the head to continue moving 3, non-professionals do not open the box without permission to move the parts of the instrument 4, the motor is strictly prohibited when the head, hands, etc. close to the chuck and moving parts, in order to avoid injury 5, in case of emergency quickly cut off the power , Check the cause and then re-power on 6, the instrument power supply should have a reliable grounding This article for Qingdao Zhongbang Instrument Co., Ltd. original article, if necessary to add reprint instructions source, unauthorized reproduction of theft, will bear responsibility!
First, the fabric friction electric charge tester is to measure the charge of the antistatic clothing after the friction charged test equipment, the use of the process should pay attention to the following points:
1. The supporting Faraday cylinder tube should be reliably grounded 2. The charge measuring device should be cleared before every experiment. 3. The measured object must be separated from the power source during the measurement. 4. Before the test, turn on the power switch to allow the machine to warm up for 15 minutes. Lined work clothes should be turned outwards, cold clothes should be removed after test liners and linings should be removed. 6. The roller friction machine should be placed on a stable table or on the ground, so as to avoid the operation is swinging and produce more noise. 7. Pins, coins, and Other sharp metal objects are thrown into the roller friction machine to avoid damaging the inner lining cloth 8. The environmental conditions for the antistatic overalls test are temperature (20±5)°C, relative humidity 40%, and point-to-point resistivity test. The instrument is a testing device for testing the resistivity of antistatic clothing. Please pay attention to the following points during use:
1. The built-in battery and external power supply can only select one of the power supply modes. Generally, it is recommended to select the external power supply. 2. When the instrument is not in use, place it in a dry and ventilated place. 3. If it is powered by the built-in battery, if it is not used for a long time, please Remove the battery from the battery compartment to prevent the battery from leaking to corrode the instrument. 4. Non-professional service personnel must not open the instrument cover to prevent electric shock from high pressure inside the instrument. Freely open the cover to disassemble, change the internal components of the instrument may lose the qualification of the instrument or increase the cost of repairs. 5, it is forbidden to use hydrochloric acid, solder paste and other corrosive fluxes to solder the measurement leads, connectors or internal components of the instrument. , In order to avoid irreparable leakage failure Third, the tensile testing machine is to detect the tensile strength of ESD clothing, breaking strength and elongation at break testing equipment, please note the following points during use:
1. The sensor equipped with this instrument is a precision device. It should avoid the impact and distortion of external force. 2. The instrument is equipped with a limit switch for the upper clamp head. When the upper clamp reaches the upper and lower limit positions, the instrument is self-protected and clamped. Stop the head to continue moving 3, non-professionals do not open the box without permission to move the parts of the instrument 4, the motor is strictly prohibited when the head, hands, etc. close to the chuck and moving parts, in order to avoid injury 5, in case of emergency quickly cut off the power , Check the cause and then re-power on 6, the instrument power supply should have a reliable grounding This article for Qingdao Zhongbang Instrument Co., Ltd. original article, if necessary to add reprint instructions source, unauthorized reproduction of theft, will bear responsibility!