Â
Structure and Working Theory
Â
      Inside the counter of water meter (mechanical part), there is one magnet embedded under the wheel pointer for 0.01 m3 of water and two reed switches beside each side of the wheel. Each time the pointer goes a circle, one group of two pulses is generated to represent 0.01 m3 of water being calculated. The pulses are converted to digital signals and recorded as metering data based on pre-set program. Then the metering data can be transmitted to a concentrator or hand-held unit.
Â
 Product Features
Mainly applicable to new construction projects, or reconstruction projects for old residential area which are inconvenient for wiring deployment.
Wireless transmission technology is applied to realize out-door meter reading, which simplified system installation by avoiding wiring deployment.
The wireless transmission distance for hand-held unit is over 200 meters in open field.
Friendly user interface for management software of background platform. Variety of formats for data output and customized link with billing system according to customers'needs.
Total volume calculation of water flowing across the pipe and wireless meter reading.
Remote valve-control to solve arrearage problem.
Three-level automatic routing to increase transmission distance.
Real-time meter reading to realize ladder-type pricing.
Fully anti-water design, functional under the water.
ERFCU design, ultra-low power consumption.
WOR remote awaking technology to reduce power consumption.
Wamr Net routing protocol to ensure data security.
High speed transmission, data reading for single meter within 1.5 seconds.
Simple and practical structure with removable battery.
Maximum Permissible Error
From minimum flux inclusive up to transitional flux: ±5%
From transitional flux up to maximum flux both inclusive: ±2% (cold water meter)
From transitional flux up to maximum flux both inclusive: ±3% (hot water meter)
Â
Model | Nominal Diameter | Metering Grade | Common Flux | Transitional Flux | Minimum Flux | Minimum Reading | Maximum Reading |
mm | Â | m 3 /h | m 3 | ||||
LXSK-15(cold) | 15 | B | 1.5 | 0.12 | 0.03 | 0.0001 | 99999.999 |
LXSK-20(cold) | 20 | B | 2.5 | 0.2 | 0.05 | 0.0001 | 99999.999 |
LXSK-25(cold) | 25 | B | 3.5 | 0.28 | 0.07 | 0.0001 | 99999.999 |
LXSFR-15(hot) | 15 | A | 1.5 | 0.15 | 0.06 | 0.0001 | 99999.999 |
LXSFR-20(hot) | 20 | A | 2.5 | 0.25 | 0.10 | 0.0001 | 99999.999 |
LXSFR-25(hot) | 25 | A | 3.5 | 0.35 | 0.14 | 0.0001 | 99999.999 |
Plate And Shell Heat Exchanger
The plate and shell heat exchanger range of heat exchangers are new generation heat exchangers, combining the best properties of the Plate & Frame and Shell & Tube heat exchangers. The plate and shell heat exchanger provides high heat transfer rates with a high pressure and temperature operating range. They have no gaskets, are compact, low fouling and can operate at close approach temperatures.The application is Hydrocarbon condensers and evaporators;Heat-recovery exchangers like feed/effluent exchangers;Overhead condensers and gas liquefiers.
At the heart of the plate and shell heat exchanger is a fully welded pack of circular plates without gaskets. This plate pack is housed within a tubular shell to provide a strong compact construction. The plate and shell heat exchanger series have a very wide operating range with capacities of up to 100 MW / units, and can operate at pressures up to 100 bar and temperatures up to 400°C. They have a low maintenance design that provides flexibility to select different material and nozzle combinations.
Plate And Shell Heat Exchanger,Full Welded Plate Heat Exchanger,Shell And Tube Heat Exchanger,Plate And Shell Heat Exchanger Condenser
Jiangsu Baode Heat-Exchanger Equipment Co.,LTD , https://www.baodeexchanger.com