Constant temperature and humidity incubator
The special constant-temperature culture device for the series of biochemical incubators and mold incubators, molds, and cultivation of micro-organisms and breeding tests is applied to ideal equipment for scientific research, production and use in the fields of bio-engineering, medical research, agriculture and forestry science, aquatic products, and animal husbandry.
Constant temperature and humidity incubator function:
Microprocessor control, with monitoring, temperature control and protection functions. In-cabinet lighting: Can observe the culture inside the box, stainless steel liner, never corrosion.
Constant temperature and humidity incubator matters needing attention and maintenance and repair 1, this box working voltage is AC 220V, 50Hz. Before use, you must pay attention to whether the power supply voltage used is consistent with the specified voltage, and ground the power outlet grounding pole as required.
2. When using electricity, avoid contact with the electrical parts of the left-hand side of the box and wipe it with a damp cloth or water.
3, the power cord can not be wrapped around metal objects, can not be placed in a hot or humid place, to prevent rubber aging and leakage.
4. Test objects placed in the box should not be over-extruded, so that the air flow, keep the box evenly heated, the inner floor near the heater, it should not be placed test objects. In the laboratory, the wind top door should be unscrewed properly in order to adjust the temperature inside the box.
5. When the incubator is placed in valuable strains and cultures, it should be observed and abnormalities should occur. Immediately cut off the power supply to avoid external or unnecessary losses.
6. When not necessary, do not open the temperature controller to prevent damage.
7. After each use, the power must be turned off. Keep the inside and outside of the box clean and the water in the tank clean.
8, when the use of high temperature, you should pay attention to careful burns.
9, the fuse tube installed in the left side of the room, the exchange need to open the side door, and must cut off the power.
10. After the packaged incubator has complied with the rules of preservation and use, the manufacturer shall replace or repair parts for the user at no cost when the product fails to work within the period from the date of delivery (with a period of one year).
The special constant-temperature culture device for the series of biochemical incubators and mold incubators, molds, and cultivation of micro-organisms and breeding tests is applied to ideal equipment for scientific research, production and use in the fields of bio-engineering, medical research, agriculture and forestry science, aquatic products, and animal husbandry.
Constant temperature and humidity incubator function:
Microprocessor control, with monitoring, temperature control and protection functions. In-cabinet lighting: Can observe the culture inside the box, stainless steel liner, never corrosion.
Constant temperature and humidity incubator matters needing attention and maintenance and repair 1, this box working voltage is AC 220V, 50Hz. Before use, you must pay attention to whether the power supply voltage used is consistent with the specified voltage, and ground the power outlet grounding pole as required.
2. When using electricity, avoid contact with the electrical parts of the left-hand side of the box and wipe it with a damp cloth or water.
3, the power cord can not be wrapped around metal objects, can not be placed in a hot or humid place, to prevent rubber aging and leakage.
4. Test objects placed in the box should not be over-extruded, so that the air flow, keep the box evenly heated, the inner floor near the heater, it should not be placed test objects. In the laboratory, the wind top door should be unscrewed properly in order to adjust the temperature inside the box.
5. When the incubator is placed in valuable strains and cultures, it should be observed and abnormalities should occur. Immediately cut off the power supply to avoid external or unnecessary losses.
6. When not necessary, do not open the temperature controller to prevent damage.
7. After each use, the power must be turned off. Keep the inside and outside of the box clean and the water in the tank clean.
8, when the use of high temperature, you should pay attention to careful burns.
9, the fuse tube installed in the left side of the room, the exchange need to open the side door, and must cut off the power.
10. After the packaged incubator has complied with the rules of preservation and use, the manufacturer shall replace or repair parts for the user at no cost when the product fails to work within the period from the date of delivery (with a period of one year).
Arc Magnet,High Performance Arc Magnets,Neodymium Arc Segment Magnet,Professional Permanent Arc Magnets
GEILI Magnetic Industry Co., LTD , https://www.geilimagnet.com